Railway

Torna ad elenco
Custom Design - 86W / AC-DC
path:C:\Inetpub\vhosts\powercontrolsystems.com\httpdocs\contenuti\prodotti\SA83-I-R-X-N1_603.jpg
url: http://www.powercontrolsystems.it/contenuti/prodotti/SA83-I-R-X-N1_603.jpg

86W / AC-DC

Railway Application
Single output AC-DC power supply unit

Input • Rated input voltage 115 - 125 - 220 - 230 Vac (90÷264Vac)
• Line frequency 46÷450 Hz
• Power factor > 0,8
• Input protection • Input Transient level (The P.S. shall not be damage when a 24Vac and 48Vac/50hz full rectified voltage is applied) • Short circuit on input line
• Input connections • Input = DIN 41612 Type H15 male Argented with Mechanical Coding
Output • Output power (max) 86W
• Hold up time 500 ms at 99V/48Hz and nominal power
• Start up time 500ms
• Rise time 100ms (from 10% to 90% to output voltage)
• Output protections • Overvoltage protection • Overload protection • Short-circuit protection
• Output connections • Output = DIN 41612 Type C96
General Features • DC-DC / AC-DC AC - DC
• Efficiency > 80% (from 70% to full load)
• Dieletric withstand voltage • Input - Output = 3,5KVrms • Input - Mechanical Ground = 3,5KVrms • Output - Mechanical Ground = 0,5KVrms
• Isolation • Comply with EN 50124-1 • Mechanical Ground - Output < 100 MOhm • Mechanical ground - input < 100 Mohm • input - Output > 200 Mohm
• Cooling Natural convection
• MTBF • 750000 h (comply with IEC
• Operating indicator • Green led = Input voltage is OK (IN OK) • Green led = Output voltage is OK (OUT OK)
• Other features Audio Noise • < 40dB (A) at 1 meter Power Supply Comply with: • NF F 16-101 • NF F 16-102 Manufacture comply with: • IPC A 610 REV. D Class 3 • RoHS
• Operating temperature -40°C ÷ +85°C
• Storage temperature -40°C ÷ +85°C
• Weight < 2,0 Kg
• Comply with • EN 50155 • EN 50121-3-2 • EN 50121-4 • EN 50124-1 • IEC 62380 • CECC 0020 • CECC 63000 • DIRECTIVE 2002/95/EC • EN 60529 • EN 61373 • EN 50125-1 • EN 50125-3 • EN 60 068-2-1 • EN 60 068-2-2 • EN 60 068-2-30 • EN 61000-4-2 • EN 61000-4-3 • EN 61000-4-4 • EN 61000-4-5 • EN 61000-4-6 • EN 55011• CEI 664 • NFC 42-801 • EN 60950-1 • EN 50129 • EN 50160 • EMCSS-VILB-TH-00157
• Application field Railway Application


Power Control Systems Italy
Manufactured by: Power Control Systems srl Italy
Model: 86W / AC-DC
Product ID: 86W / AC-DC