Input |
• Rated input voltage |
90÷264Vac |
|
• Line frequency |
50/60Hz |
|
• Leakage current to GND (max) |
0,5mA max at 233Vac 50Hz |
|
• Input protection |
• Inrush current limitation• EMI filter• Line fuse |
Output |
• Output voltage |
36W |
|
• Output voltage temp drift |
0.02%/°C |
|
• Output voltage long term stability |
Better than 1% after 24 hours |
|
• Output power (max) |
30÷48W (see table) |
|
• Temp power derating |
2%/°C (50÷70°C see diag.) |
|
• Hold up time |
12msec at 110Vac/40W output |
|
• Output protections |
• Overvoltage protection• Overcurrent protection• Short circuit protection |
General Features |
• DC-DC / AC-DC |
AC - DC |
|
• Efficiency |
>75% |
|
• Dieletric withstand voltage |
• Input - Output : 3750Vac (on insulatingcomponents)• Input - P.E. : 1750Vac |
|
• Isolation |
• Output - P.E.: 500Vdc |
|
• See table for |
• Output voltages and currents• Total regulations• Output ripple and noise |
|
• Cooling |
• Natural convection (see table - Imax1)• Forced ventilation (see table - Imax2 at220Vac) |
|
• Other features |
Optional:• C - Closed box• DC - DC input for AC-DC units• H - RAIL-DIN mounting |
|
• Operating temperature |
0°C to 50°C |
|
• Storage temperature |
"-40°C to 85°C" |
|
• Switching frequency |
40KHz typ. |
|
• Weight |
board: 260g; closed: 520g |
|
• Comply with |
• EN 50081-1• EN 61000-6-2• EN 60950-1• CE |
|
• Dimensions |
127x76x35 |
|
• Application field |
Industrial application |