Input |
• Rated input voltage |
90÷260Vac with PFC
115/230Vac ±15%, jumper on pcb |
|
• Line frequency |
50/60Hz |
|
• Leakage current to GND (max) |
Max 2mA at 50Hz |
|
• Input protection |
• Start-up peak current limitation: 30A at
Vin=220Vac
• Fuses on both input lines and EMI filter |
|
• Input inhibit |
• TTL/CMOS comp. low active |
Output |
• Output voltage |
1440W |
|
• Output voltage temp drift |
0.01%/°C typ. |
|
• Output voltage long term stability |
Better than 1% after 24 hours |
|
• Remote sense compensation |
0.5V max |
|
• Output power (max) |
1440W |
|
• Temp power derating |
2%/°C (50÷70°C) |
|
• Hold up time |
15msec min. |
|
• Start up time |
60msec typ. |
|
• Output protections |
• Over load
• Short circuit
• Over voltage : at Vo + 25% typ.
• Over temperature : with thermostatic sensor |
|
• Output signals |
• AL - Alarm signal |
General Features |
• DC-DC / AC-DC |
AC - DC |
|
• Efficiency |
75÷85% (depending on output voltage) |
|
• Dieletric withstand voltage |
• Input - Output : 3750Vac (on insul.comp.)
• Input - P.E.: 1750Vac |
|
• Isolation |
• Output - P.E.: 500Vdc |
|
• See table for |
• Output voltages and currents
• Line and load regulation
• Output ripple and noise |
|
• Cooling |
Forced ventilation |
|
• Operating indicator |
• Green led : input voltage
• Yellow led : over temperature
• Red led : power failure |
|
• Other features |
Optional:
• BAL - Load balance adjust. for parallel
connection
• DC - DC input for AC-DC units
• DD - Output decoupl. diode for parallel
connection
• PF - Power fail/reset signals
• PFC - Power factor correction circuit
• PROG - Programmable Vout |
|
• Operating temperature |
0°C to 50°C |
|
• Storage temperature |
"-25°C to 85°C" |
|
• Switching frequency |
30kHz ca. |
|
• Weight |
6500g |
|
• Comply with |
• EN 50081-1
• EN 61000-6-2
• EN 60950-1
• CE |
|
• Dimensions |
157x210x265 |
|
• Application field |
Industrial Application |