Input |
• Rated input voltage |
16÷36 Vdc (14,4÷40Vdc for transient <=100ms) |
|
• Input protection |
• RFI filter • Input fuse • Reverse polarity |
Output |
• Output protections |
• Over load protection • Short circuit protection • Over voltage protection |
|
• Output signals |
• Sense1+ • Sense1- • Out_OK+ • Out_OK- • Inhibit (connect to V1- to enable outputs) |
General Features |
• Efficiency |
85% typ. |
|
• Dieletric withstand voltage |
• Inputs - (Outputs+Out ok+P.E.) = 1500Vdc • (Inputs+Outputs+Out ok) - P.E. = 500Vdc • Out ok - (Inputs+Outputs+P.E.) = 750Vdc |
|
• See table for |
• Output Nominal power • Output voltages and currents • Line and load regulation • Output ripple and noise |
|
• MTBF |
70000 hours MIL-HDBK-217 Notice F (GM -50°C) |
|
• Operating indicator |
• Led 1 : Out OK (Outputs OK) • Led 2 : +24/1 V (Output Vo1 presence) • Led 3 : +24/2 V (Output Vo2 presence) • Led 4 : Vin (Battery input presence) |
|
• Operating temperature |
-25° ÷ +85°C |
|
• Storage temperature |
-40°C ÷ +85°C |
|
• Humidity |
< 75% (95% for 30 consecutive days) |
|
• Comply with |
• EN50155 • EN50121-3-2 • EN50125-1 (T3 class) • FSST306158 • IP 40 for ambiental protection • EN 60068-2-2 NORM • HD 323.2.30 • NF C 20-714 NORM • CEI 801.4 • EN60950 |
|
• Dimensions |
220x100x35 |
|
• Application field |
Railway Application |