Input |
• Rated input voltage |
115 - 125 - 220 - 230 Vac (90÷264Vac) |
|
• Line frequency |
46÷450 Hz |
|
• Power factor |
> 0,8 |
|
• Input protection |
• Input Transient level (The P.S. shall not be damage when a 24Vac and 48Vac/50hz full rectified voltage is applied) • Short circuit on input line |
|
• Input connections |
• Input = DIN 41612 Type H15 male Argented with Mechanical Coding |
Output |
• Output power (max) |
86W |
|
• Hold up time |
500 ms at 99V/48Hz and nominal power |
|
• Start up time |
500ms |
|
• Rise time |
100ms (from 10% to 90% to output voltage) |
|
• Output protections |
• Overvoltage protection • Overload protection • Short-circuit protection |
|
• Output connections |
• Output = DIN 41612 Type C96 |
General Features |
• DC-DC / AC-DC |
AC - DC |
|
• Efficiency |
> 80% (from 70% to full load) |
|
• Dieletric withstand voltage |
• Input - Output = 3,5KVrms • Input - Mechanical Ground = 3,5KVrms • Output - Mechanical Ground = 0,5KVrms |
|
• Isolation |
• Comply with EN 50124-1 • Mechanical Ground - Output < 100 MOhm • Mechanical ground - input < 100 Mohm • input - Output > 200 Mohm |
|
• Cooling |
Natural convection |
|
• MTBF |
• 750000 h (comply with IEC |
|
• Operating indicator |
• Green led = Input voltage is OK (IN OK) • Green led = Output voltage is OK (OUT OK) |
|
• Other features |
Audio Noise • < 40dB (A) at 1 meter Power Supply Comply with: • NF F 16-101 • NF F 16-102 Manufacture comply with: • IPC A 610 REV. D Class 3 • RoHS |
|
• Operating temperature |
-40°C ÷ +85°C |
|
• Storage temperature |
-40°C ÷ +85°C |
|
• Weight |
< 2,0 Kg |
|
• Comply with |
• EN 50155 • EN 50121-3-2 • EN 50121-4 • EN 50124-1 • IEC 62380 • CECC 0020 • CECC 63000 • DIRECTIVE 2002/95/EC • EN 60529 • EN 61373 • EN 50125-1 • EN 50125-3 • EN 60 068-2-1 • EN 60 068-2-2 • EN 60 068-2-30 • EN 61000-4-2 • EN 61000-4-3 • EN 61000-4-4 • EN 61000-4-5 • EN 61000-4-6 • EN 55011• CEI 664 • NFC 42-801 • EN 60950-1 • EN 50129 • EN 50160 • EMCSS-VILB-TH-00157 |
|
• Application field |
Railway Application |